EB Life Safety provides independent third-party review of fire protection and life safety designs for new construction projects.

Independent Review Scope

A third-party fire protection review provides an additional technical check of drawings, specifications, calculations, narratives, and system interfaces. EB Life Safety first defines whether the review covers code compliance, design criteria, constructability, delegated submittals, smoke control, egress, or a focused risk. Independence is most useful when the reviewer has the complete current set and the owner identifies the decisions that need an outside perspective.

Traceable Comments

Review comments should identify the sheet, detail, specification, calculation, or requirement involved and explain why coordination is needed. We can compare the design with the adopted Florida Building Code, applicable NFPA standards, approved basis, and AHJ comments, while noting where an interpretation belongs with the AHJ. A third-party review does not replace the engineer of record's design responsibility or the permit review.

Closeout and Design Coordination

After comments are answered, an independent reviewer can check whether revisions resolve the stated issue and whether changes create new conflicts with alarm, suppression, smoke control, egress, or emergency power. A response log helps the owner track open items through permit, construction, testing, and closeout. The level of review and any reliance on it should be stated clearly in the engagement.

Making an Independent Review Actionable

A third-party report should be organized so the project team can act on it without guessing what the reviewer meant. Each comment can identify the document and revision reviewed, the relevant code or design criterion, the observed concern, the risk or coordination effect, and a suggested next step. Comments should distinguish a clear conflict from an item requiring additional information, a preference, or an AHJ interpretation. EB Life Safety can use a review matrix that assigns each item to the architect, engineer of record, contractor, owner, or AHJ and records the response and closure evidence. The reviewer should also identify what was not included: calculations not provided, field conditions not observed, delegated design not reviewed, or product listings requiring confirmation. This protects the owner from relying on a review beyond its scope. When a revision is issued, the team should check affected plans, details, specifications, schedules, narratives, and system sequences rather than closing a comment from a single sheet alone. A change to a rated wall can affect penetrations, alarm devices, sprinkler coverage, egress, and smoke-control boundaries. A change to an equipment room can affect access, power, ventilation, fire pump or generator arrangements, and maintenance clearances. The review closes when the response addresses the concern and the revised document supports the response, not merely when a meeting records agreement. Final reliance should be established by the owner and design professionals, and permit approval remains with the AHJ. This disciplined process makes an independent review a useful risk-control step instead of a duplicate plan stamp. The reviewer should state the document date, review method, and whether the work was a desktop review, coordination review, or field review. A review based on incomplete or superseded information should be re-scoped when the complete set arrives. This transparency lets the owner compare open risk with project decisions and prevents the report from being treated as a permit approval or construction certification.

Related Services

Frequently Asked Questions

When is an independent fire protection review useful?

It can help before permit submission, at a major design milestone, during value engineering, or when an owner wants an additional check of complex system interfaces.

Does the reviewer approve the permit?

No. The design professional remains responsible for the design, and the AHJ remains responsible for permit approval. The review provides technical observations and recommendations.

What files are needed for review?

A current coordinated drawing set, specifications, calculations, narratives, schedules, code basis, and relevant AHJ comments allow a meaningful review. Incomplete files limit the conclusions.